21 Aug 2025
Design makes light travel in a circle so it can interact multiple times with target.
How can one achieve the best possible image in a microscope without destroying the sample? A new design from the Technical University of Vienna, Austria (TU Wien), enables what its developers call “gentle imaging with maximum image quality”.Conventionally, if a detailed image is wanted, the subject needs to be illuminated with a lot of light. In microscopy, however, too much light is often harmful to the sample – for example, when imaging sensitive biological structures or investigating quantum particles. The aim is therefore to gather as much information as possible about the object under observation with a given amount of light.
In a collaboration with the University of Vienna and the University of Siegen, Germany, the TU Wien researchers have now developed a novel way to achieve this: they store the light in a resonator in which the sample is also located. This allows them to obtain a clearer signal than with other methods.
The technique is described in Nature Scientific Reports.
Better signal by light scattering
“In a normal microscope, the light hits the sample once and then enters a lens,” said Maximilian Prüfer, who led the study as part of his Esprit fellowship from the FWF at the Atomic Research Institute of TU Wien. “In our microscope, we place the sample in an optical resonator – between two mirrors.”
To turn this resonator into a microscope, the team developed an unusual experimental setup with additional lenses: after the light beam has passed through the sample, it is guided in a circle and hits the sample again.
“Now the sample is illuminated again, but not with a normal, uniform beam of light as in the beginning, but with a beam of light that already contains the image of the sample, so to speak,” explained Oliver Lueghamer, of TU Wien, who built the microscope as part of his master’s thesis.
Similar to a stamp that is pressed several times on the same spot, producing a clearly visible image even with faint ink, the image of the sample becomes clearer and clearer as it completes several rounds in the microscope.
Both theoretical calculations, which were developed in collaboration with Thomas Juffmann (Vienna) and Stefan Nimmrichter (Siegen), and experiments show that this method provides more information than other microscopy techniques at a given light intensity. “The key figure is the signal-to-noise ratio,” said Prüfer. “This ratio is better here than with other methods due to multiple scattering with the same disturbance of the sample.”
Stable even with minor disturbances
However, the practical suitability of the new method also depends on how susceptible it is to disturbances: “When using optical resonators, as we do, it is often important to keep their length extremely constant,” added Prüfer.
“Normally, you have to go make a great effort to ensure that the distance between the two mirrors varies only minimally, otherwise the desired effect is lost. With our method, however, this is not the case.”
The distance between the mirrors can also show a certain instability without the enhancement disappearing. “This is important because it means that the method not only works in theory, but can also be used in practice with manageable effort,” said Prüfer. One of the goals of the new microscopy technique is to image ultra-cold Bose-Einstein condensates and thereby study their quantum physical behavior.