1535nm eye-safe laser

22 May 2019

Description

1535 solid-state eye-safe laser—Ultra compact eye-safe laser for ranging finder

Lasers with emission wavelengths longer than 1.4 μm are often called “eye-safe”, because light in that wavelength range is strongly absorbed in the eye’s cornea and lens and therefore cannot reach the significantly more sensitive retina. Obviously, the quality “eye-safe” depends not only on the emission wavelength, but also on the power level and the optical intensity which can reach the eye. Eye-safe lasers are particularly important in 1535nm-laser-for-ranging-and-radar cases where light needs to be transmitted over substantial distances in open air. Examples are laser rangefinders and free-space optical communications.

The wavelength of 1535nm is just in the position of the human eye and the atmospheric window, so it has been widely concerned in the fields of laser ranging and electronic communication. Er,Yb:glass lasers are most commonly used for laser rangefinders with a low pulse repetition rate (less than 10 Hz). Our eye-safe laser have already used in ranging finder and its ranging range is 3-5km with high stability, which applied in Gun aiming and UAV pod.

Parameter

Parameter Unit Min Typical Max
Laser wavelength nm 1533 1534 1535
working frequency Hz / 1-10 10
Pulse Width ns 4.3 4.6 5
Peak power Kw 20 ≥20 28
Spot size mm Φ0.16 Φ0.17 Φ0.18
Divergence angle mrad 9 10 12
Operating temperature ˚C -45 – +65 -45 – +65 -45 – +75
Overall dimension mm 26.3×9.9×7.9 26.4×10×8 26.5×10.1×8.1
weight g 7 8 8.5
Energy Stability(RMS,104shots) % 0.6 0.8 1
M-Square NA 1.1 1.2 1.3
LD Working Current A 7.5 7.5 7.5
LD Working Current pulse width ms 1.2 1.4 1.7
LD Working Voltage V 1.7 1.8 1.9
Power Consumption W 0.017 0.021 0.033
Beam Alignment Tolerance (Off-axis Angle) mrad 1 8 16
Beam Alignment Tolerance (Position(△r)) mm 0.1 0.2 0.3
Storage Temperature ˚C -45 / 80
Operating Humidity R.H. 5% 40% 85%
Shock NA / 15g, 0.5ms, 6 shocks /
3 axes, 2 shocks/axis
Vibration NA / 20~2000Hz, 0.02g2/Hz /
3 axes, 1hr/axis
Expected Lifetime Shots / 2×107 /

Feature

  • Beam quality near diffraction limit

  • Small volume

  • Low power consumption,

  • No temperature control

  • Open and be used

  • High reliability

  • Good stability

  • Wide temperature range

Application

  • Laser ranging

  • Laser irradiation

  • Laser radar

  • Target recognition

  • Laser medical treatment

  • Optical fiber communication