Optics.org
daily coverage of the optics & photonics industry and the markets that it serves
Featured Showcases
Photonics West Showcase
Press Releases
Menu
Press Release

Stellenbosch University study the morphology and mechanical properties of snake fangs using the Deben CT500.

Date Announced: 13 May 2019

In 2017 Stellenbosch University, South Africa undertook an experimental campaign which focused on analysing venomous snake fangs. The motivation behind the campaign was to understand in detail the internal and external morphology and mechanical properties of snake fangs. The study focused on comparing the maximum Von Mises stress values when a load was applied to the tip of the fang (3 fang phenotypes were tested).   

Each individual fang was loaded vertically in rigid foam and the foam was attached to a glass rod for microCT scanning and high-resolution X-ray CT scans were recorded. Morphological analysis was performed measuring both the fang length and diameter amongst others. Physical compression tests were carried out for two selected fangs using the Deben CT500 stage. Each fang was epoxy-glued onto a polymer disk, this disk was then attached to the top jaw of the CT500. An additional polymer disk topped with a layer of rigid foam was then attached to the bottom jaw. The two disks were slowly moved together at 0.2mm/min (in compression mode) and the rigid foam was pierced with no measured load (~0.1N) showing that fangs are excellent at piercing! The cross-sectional area of the fang was taken at the point of failure to allow calculation of stress. The total length of the fang was taken for calculation of strain. During the compression process live X-ray images were recorded and load tests were successfully recorded for 2 fangs. 

The results obtained indicate that closed fused fangs are generally longer, more slender and more curved than other type of fangs. Open groove fangs are shorter and not as curved but have thicker walls and higher material volume. It was also observed that although most fangs have sharp edges, the specific type of sharp edge varies from fang to fang.

Using morphological analysis and structural mechanics simulation under microCT it was discovered that the 3 fang phenotypes all have distinctive characteristics aside from the venom-conducting canal (including shape, curvature and sharp edges). Results obtained relating to stress values show that all fang types respond in a similar way to being placed under load, both parallel and laterally. Lateral loads cause stresses 3 times greater than parallel loads. The results show that the piercing and cutting ability of the fangs are key to their success as the fangs are not physically very strong – this relates back to the differences discovered in the fangs sharp edges.

 According to Professor Anton Du Plessis: “The Deben CT500 stage made it possible to achieve something incredible here: we measured the compressive properties of two snake fangs – which are only 5mm long each! The failure location correlates with simulations of microCT data of the fangs – these are the location of high stress in the fang”

 For more information on this fascinating work, including 3D print models and microCT data of snake fangs, see the publications below or visit Professor Du Plessis’ research page: http://blogs.sun.ac.za/duplessis.

 

References:

 Article:  https://academic.oup.com/gigascience/article/7/1/gix126/4750779?searchresult=1

[1]         C. Broeckhoven, A. du Plessis, Has snake fang evolution lost its bite? New insights from a structural mechanics viewpoint, Biol. Lett. (2017). doi:10.1098/rsbl.2017.0293.

[2]         A. Du Plessis, C. Broeckhoven, S.G. Le Roux, Snake fangs: 3D morphological and mechanical analysis by microCT, simulation, and physical compression testing, Gigascience. 7 (2018) 1–8. doi:10.1093/gigascience/gix126.

 

About Deben

Deben are a precision engineering company, established in 1986. They specialise in the field of in-situ tensile testing, motion control and specimen cooling for microscopy applications. The main product groups include: motor control systems, in-situ micro-tensile stages, Peltier heating & cooling stages, detectors for SEMs and electro-static beam blankers. The company also makes custom and OEM versions of these products to specifically meet customer requirements.

Deben provide consultancy, design and prototype manufacturing services. In house facilities include SolidWorks and SolidEdge 3D CAD and COSMOS finite element analysis software, CNC machining, electronics design and manufacture and software design using Visual C++, Microsoft.net and DirectX.

Deben UK Ltd. is a subsidiary company of UK based Judges Scientific plc. For details on Deben and all its products & solutions, visit www.deben.co.uk.

Contact


Deben UK Limited
Brickfields Business Park
Old Stowmarket Road
Woolpit, Bury St Edmunds
Suffolk IP30 9QS, UK
T +44 (0)1359 244870
www.deben.co.uk
 
Written by: Abigail Royal (Sales and Marketing Administrator) abigailr@deben.co.uk
Sales Contact: Paul Gadsby (Sales Director) paulg@deben.co.uk
 

E-mail: abigailr@deben.co.uk

Web Site: deben.co.uk

Liquid Instruments Webinar
© 2024 SPIE Europe
Top of Page